Setting Up System Options
 
 LTPS-UM-8013-03
20
August 30, 2002
 D3LX CO and RMT Modules
9600 baud 
No parity
8 data bits
1 stop bit
Hardware flow control to OFF
Figure 11.
Connecting a Maintenance Terminal to the SCU
5
At the maintenance terminal, press 
. The Enter User Name field appears.
C
ONNECTING
 
A
 M
AINTENANCE
 T
ERMINAL
 
TO
 
THE
 D3RCAM C
RAFT
 
P
ORT
1
Locate the D3RCAM in the remote cabinet. The D3RCAM craft port is located on the front of the D3RCAM. 
2
Select the cable for use between the craft port and the maintenance terminal with a DB-9 (male) connector at 
one end and a maintenance terminal connector at the other end. 
3
Connect one end of the interface cable to the maintenance terminal and the other end to the D3RCAM craft 
port as shown in 
4
Start a terminal emulation program such as Procomm that emulates a VT100 terminal.
The default port configuration for the SCU craft port is CRAFT. Ports 2 and 3 must be configured 
for CRAFT before the craft interface may be accessed via these ports. 
Craft port
Maintenance
terminal
Serial
COM port
Interface cable
LEC
ENTER