ADC SG-1 Manuel D’Utilisation

Page de 226
6-24
Displaying show mpls-labels commands
It displays the incoming labels binding received from the neighbors and the out-going label binding distributed by the 
system. When no specific FEC is defined, the system shows all FECs.
Usage
Show mpls-labels <standard | vc> <out | in> [<FEC identifier>]
Parameter(s)
<standard | vc>
Standard labels are the first labels on the stack, while vc labels (tunnels) are the second lable on the stack.
<out | in>
Lables that are out-going or incoming.
<FEC identifier>
It is the FEC (Forward Equivalence Class) identifier.
Example(s)
Standard in:
Standard out:
Host> show mpls-labels
Note:
 The system default value is 0 (which means all FECs).
Host>  show labels standard in
FEC ID
 IP destination FEC
Label
Next-Hop
Interface
 1
192.168.1.0/24             123876     10.0.1.8        Ethernet 1
 2
212.8.1.0/24                1034
10.0.1.3        Ethernet 1
Host>  show labels standard out
FEC ID
 IP destination FEC
Label
 1
192.168.1.0/24             123876
 2
212.8.1.0/24                1034