ADC SG-1 Manuel D’Utilisation
6-24
Displaying show mpls-labels commands
It displays the incoming labels binding received from the neighbors and the out-going label binding distributed by the
system. When no specific FEC is defined, the system shows all FECs.
system. When no specific FEC is defined, the system shows all FECs.
Usage
Show mpls-labels <standard | vc> <out | in> [<FEC identifier>]
Parameter(s)
<standard | vc>
Standard labels are the first labels on the stack, while vc labels (tunnels) are the second lable on the stack.
<out | in>
Lables that are out-going or incoming.
<FEC identifier>
It is the FEC (Forward Equivalence Class) identifier.
Example(s)
Standard in:
Standard out:
Host> show mpls-labels
Note:
The system default value is 0 (which means all FECs).
Host> show labels standard in
FEC ID
IP destination FEC
Label
Next-Hop
Interface
1
192.168.1.0/24 123876 10.0.1.8 Ethernet 1
2
212.8.1.0/24 1034
10.0.1.3 Ethernet 1
Host> show labels standard out
FEC ID
IP destination FEC
Label
1
192.168.1.0/24 123876
2
212.8.1.0/24 1034