ADC SG-1 Manuel D’Utilisation

Page de 226
7-6
Configuring Ethernet Redundancy
The system supports redundancy between 0\1 and 0\2 ethernet interface or between 1\1 or 1\2 Ethernet interface. 
The system, automatically while detects a malfunction in the working Ethernet (for example link down), switches to 
the protecting (redundant) Ethernet interface.
Using the port-ethernet redundancy-enable command
Use this command to configure Ethernet port redundancy.
Usage
port-ethernet redundancy-enable <working slot>\<working port> <protection 
slot>\<protection port> <non-revertive | revertive>
Parameter(s)
<working slot>
This is the working Ethernet interface slot number; valid values include 1 or 2.
<working port>
This is the working Ethernet interface physical port number; the value range is 1 to 3.
<protecting slot>
This is the protecting Ethernet interface slot number; valid values include 1 or 2.
<protecting port>
This is the protecting Ethernet interface physical port number; the value range is 1 to 3.
<non-revertive>
This configures non-revertive mode.
<revertive>
This configures revertive mode.
The slot number that you want to configure (see 
Table 7-3. Configure Ethernet ports
Host(config)# port-ethernet redundancy-enable
Card Type
Slot\Port
Slot\Port 2
Gigabit Front I/O
0\1
Gigabit Rear I/O
0\2
Gigabit Front (PMC) I/O
1\1
1\2