ADC H2TU-C-319 List 4E Manuel D’Utilisation

Page de 88
LTPH-UM-1049-02, Issue 2
 
Testing
H2TU-C-319 List 4E
January 9, 2002
 57
SmartJack Loopback Commands
The HiGain HDSL2 SmartJack (SMJK) Loopback (LPBK) commands allow you to use in-band, out-of-band, and 
universal codes to initiate and terminate loopback testing of the HiGain HDSL2 circuit. (See 
 for additional information.)
M
ANUAL
 L
OOPBACK
 S
ESSION
A manual loopback session allows you to select any one of the HiGain HDSL2 loopbacks listed in 
.
Setting the Loopback Time-Out Option
Before initiating a loopback session, verify that the Loopback/MTA Time-out parameter is set to the desired 
setting. 
1
Use the MODE and LBK pushbuttons as described in 
The Loopback Time-out parameter is also user-selectable from the System Settings screen when using a 
maintenance terminal.
2
Select the desired setting:
NONE (time-out disabled)
20 minutes
60 minutes
120 minutes (default setting)
Activating Manual Loopback Mode
To initiate a manual loopback session:
1
Press both the MODE and LBK pushbuttons on the front panel for at least 3 seconds. The following message 
appears on the front-panel display:
MAN LPBK NLO?
With the exception of SmartJack, any of the HiGain HDSL2 loopbacks can be executed using the 
MODE and LBK pushbuttons. 
When executing a manual loopback session using the MODE and LBK pushbuttons:
The next loopback option can be displayed by pressing the MODE pushbutton, however, the 
previously activated loopback remains active until the LBK pushbutton is pressed, which 
activates the new loopback. 
If neither pushbutton is pressed for a period of 30 seconds and no loopback is in effect, the 
manual loopback session terminates and the display returns to normal mode. 
If any loopback is in effect, the 30-second time-out is inhibited. The active loopback and the 
manual loopback session continue until the loopback times out in accordance with the LBTO 
setting. 
Only the SMJK loopback can exist with other network loopbacks at any given time. 
If there is an active loopback, pressing the MODE and LBK pushbuttons for 3 or more 
seconds terminates any active loopback, ends the manual loopback session and returns the 
display to normal mode.