Appendix C - Ground Faults
HDU-409 Lists 1, 2, and 3
April 30, 2003
 29
A
PPENDIX
 C - G
ROUND
 F
AULTS
G
ROUND
 F
AULT
 D
ETECTION
The HDU-409 has Ground Fault Detection (GFD) circuits as described in 
R7-1, Section 7.2.1 of GR-1089 CORE, Issue 1, Revision 1, December, 1996.
When used with HiGain line units, ground faults occurring at any point along 
any span are immediately detected. Ground fault conditions shut the HiGain 
circuit down. The line unit periodically tries to apply power to the first span 
to determine whether the fault condition is still present. As long as the 
condition exists, the power cycling and ground fault protection continues. To 
discontinue the ground fault protection, locate and repair the fault in the 
cable.
Circuits containing both the HDU-409 and older doublers without a GFD 
circuit also support this new ground fault detecting feature, provided the 
doubler nearest the HLU is an HDU-409.
To operate properly, the ground fault circuit requires that the 
doubler enclosure ground plane be securely connected to 
earth ground. Failure to do so can cause false triggering of the 
GFD circuit.