Provisioning
H2TU-C-388 List 1
June 6, 2000
 17
 describes the Standard Config screen options and lists their front-panel display codes. 
describes the ADC Config screen options. Selections in bold typeface are the factory default settings.
Table 5.
HiGain Line Unit List 1 Standard Config Screen Options 
Standard Config 
Screen Options
Screen 
Display 
Code
Selection
Description
Loopback 
Timeout
LBTO
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
Loop Attenuation 
Threshold
LATT
0 through 40 dB Determines the maximum loop attenuation before an alarm is declared. The 
loop attenuation threshold can only be set through the HiGain HDSL2 
maintenance screens. 
35 dB
Default value. Zero disables the alarm.
Margin Threshold
MARG
0 to 15 dB
Determines the minimum allowable margin below which a system alarm can 
occur. Zero disables the alarm.The Margin Alarm Threshold can only be set 
through the HiGain HDSL2 maintenance screens. 
4dB
Default value.
DS1 Frame 
Formatting 
FRMG
AUTO
Configures the HiGain system to operate in an auto-framing (AUTO) mode. It 
detects and locks to both SF or ESF DS1 frame patterns. Line and path 
performance parameters are maintained and displayed. Unframed payloads 
will cause the ES-P and SES-P counters to increment.
SF
Configures the HiGain system to search for the SF framing pattern at its DS1 
input.
ESF
Configures the HiGain system to search for the ESF framing pattern at its DS1 
input.
UNFR
Configures the same as AUTO except unframed payloads do not cause the 
ES-P and SES-P counters to increment.
DS1 Line Coding
(see 
)
DS1
AUTO
The H2TU-C-388 and H2TU-R monitor the incoming DS1 bit streams for the 
B8ZS code. If the H2TU-R detects this code, the H2TU-C enters B8ZS output 
mode. The H2TU-C reverts back to AMI output mode if no B8ZS codes are 
received at the H2TU-R input for 5 seconds. Similarly, when the H2TU-C 
detects the B8ZS code, the H2TU-R enters B8ZS mode and returns to AMI 
mode if no B8ZS code is received at the H2TU-C input for 5 seconds. 
B8ZS
Places both the H2TU-C-388 and H2TU-R into B8ZS mode.
AMI
Places both the H2TU-C-388 and H2TU-R into AMI mode. 
H2TU-C 
Equalization
EQL
0
Sets the Equalizer to DSX-1 for 0 to 132 feet.
See 
.
133
Sets the Equalizer to DSX-1 for 133 to 265 feet.
266
Sets the Equalizer to DSX-1 for 266 to 398 feet.
399
Sets the Equalizer to DSX-1 for 399 to 532 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
H2TU-R Line 
Buildout 
RLBO
0 dB
Sets the DS1 receive level output toward the Customer Interface (CI). Can only 
be set through the HiGain HDSL2 maintenance screens.
-7.5 dB
Sets the DS1 RLBO level toward the CI to -7.5 dB.
-15 dB
Sets the DS1 RLBO level toward the CI to -15.0 dB.
Alarm Pattern
ALMP
AIS
Enables the HiGain system to output an AIS payload at its DS1 ports for LOSW 
and DS1 LOS. Se
 for LOS/AIS response priorities.
LOS
Enables the HiGain system to output an LOS condition at its DS1 ports for 
LOSW and DS1 LOS.
Continued