Provisioning
 
 152-388-100-02, Issue 2
20
June 6, 2000
 H2TU-C-388 List 1
DS1 BER (DBER) Option. 
The DS1 BER alarm occurs when any of the DS1 or DSX-1 performance 
monitoring parameters listed in 
 exceed the counts shown for the 24-hour period between 12:00:00 AM 
through 11:59:59 PM. These thresholds correspond to a 10
-6
 BER. All PM counters clear to zero at 12:00:00 AM 
or when Master Clear is selected. 
Resetting the H2TU-C
To reset the HiGain Line Unit to its original factory defaults:
1
Type 
 to select the Config menu.
2
Use the 
 and 
 arrow keys to select Set Factory Defaults, then press 
.
3
Type 
 if you are certain you want to reset the H2TU-C, or press 
 to cancel this action.
Figure 9.
Configuration Menu - Reset to Factory Defaults
Table 7.
DS1/DSX-1 24-hour PM Threshold 
Parameter
Threshold Count
CV-L (BPV) 
133,400
ES-L, ES-P, PRM-NE, PRM-FE
648
SES-L, SES-P
100
UAS-P, UAS-L
10
Resetting the H2TU-C-388 to its original factory settings may cause interruption of service.