Testing
H2TU-C-388 List 1
June 6, 2000
 41
Special Loopback Commands
In addition to the GNLB loopback command mode, a HiGain system can be configured for one of five special 
loopback command modes. These are selected from the maintenance terminal System Settings screen (see 
) or by using the MODE and SEL buttons (see 
). Once a loopback mode is 
activated, other loopback commands can be sent by a test set connected to the craft port of the H2TU-C or 
H2TU-R (see 
 and 
 for list of SPLB commands).
A1LB through A5LB are five special, addressable, repeater loopback modes which are supported by the 
H2TU-C-388 List 1. These loopback modes provide the HiGain system with sophisticated maintenance and 
troubleshooting tools. A1LB, A2LB, and A5LB are patterned after the Teltrend addressable DS1 repeater 
loopbacks. A3LB and A4LB are patterned after the Wescom addressable DS1 repeater loopbacks. All five SPLBs 
have been enhanced to handle the specific requirements of the following HiGain customers:
A1LB (Teltrend) = Southwestern Bell
A2LB (Teltrend) = Southwestern Bell
A3LB (Wescom) = New England Telephone
A4LB (Wescom Mod 1) = New York Telephone
A5LB (Teltrend Mod 1) = Southern New England Telephone (SNET), Southwestern Bell, Pacific Bell
The A1LB loopback selection complies with that proposed for HDSL2 systems in the T1E1.4/92 recommendation 
with the following additions:
Query loopback
IOR (Intelligent Office Repeater) powerdown
Four loopback time-out choices
Initiation from either end
Repeating bit error signatures
Alternate query loopback
These additions make A1LB identical to A2LB. A1LB is given a separate identity to allow future DS1/E1 
enhancements to be added without affecting A2LB.
A5LB differs from A2LB in that A5LB does not block the arming code from exiting the H2TU-C-388 into the 
network. A1LB and A2LB can be configured to do one of the following:
Block the arming code (after 2 seconds) from exiting the H2TU-C into the network, and replace it with the 
AIS code.
Unblock the AIS code by executing the Far-End Activate code. (Since A5LB never blocks the arming code 
from exiting the H2TU-C, the Far-End Activate code is not available in A5LB.) 
A3LB differs from A4LB in that A3LB supports the additional (1-in-6) SMJK loopback command.