ADC H4TU-C-319 List 1 Line Unit Manuel D’Utilisation

Page de 79
LTPH-UM-1031-03, Issue 3
 
Monitoring System Activity and Performance
H4TU-C-319 List 1
September 12, 2003
 35
U
SING
 
THE
 P
ERFORMANCE
 S
CREENS
 
TO
 V
IEW
 A
LARM
 D
ATA
To access the alarm history screens:
1
Press 
 to select the Performance screen.
2
Press the 
 to select an interface (H4TU-C DS1, H4TU-R DS1, H4TU-C HDSLH4DU-1 NET 
HDSL, H4DU-1 CPE HDSL, H4DU-2 NET HDSL, H4DU-2 CPE HDSL, or H4TU-R HDSL), then press 
.
3
Press the 
 until Alarm History is selected, then press 
. (To clear the selected alarm history 
screen, press 
.)
Alarm History at the DS1 Interface
The Alarm History screen reports DS1 statistics for the H4TU-C (
) and the H4TU-R (
) on a continuous basis. The types of alarms reported are described in 
. Current alarms 
are shown in reverse video.
Figure 22.
H4TU-C DS1 Alarm History Screen
P
SPACEBAR
ENTER
SPACEBAR
ENTER
L
Monitor  
Performance
  Event Log  Config  Inventory  Report  Rlogon         Help
                       H4TU-C DS1  Alarm History
-----------------------------------------------------------------------------
 Alarm        First                 Last               Status       Count
LLOS         01/30/02                                  ALARM        12
LAIS                                                   OK           0
DBER                                                   OK           7
LOF          01/30/02                                  OK           0
                         Press: C(l)ear Alarm History
-----------------------------------------------------------------------------
Use <Space> to cycle through 
    Interface  :  H4TU-C DS1
choices and <Enter> to view  
    Statistics :  
Alarm History
 ID: xxxx--xxxx--xxxx—-xxxx   02/01/2002 12:30:01   H4TU-C        System: Alarm