ADC H2TU-C-231 Manuel D’Utilisation

Page de 74
LTPH-UM-1109-01, Issue 1
Testing
H2TU-C-231 List 2
January 9, 2002
41
Alarm Option for Digital Loop Carrier (DLC) Feed
To improve HiGain HDSL2 compatibility with the switch-to-protect features used in DLC feeder applications, the
H2TU-C-231 has an Alarm Pattern (ALMP) option that allows you to select either an AIS or LOS DS1 output
payload for the following alarms:
LOSW on any loop
LOS DS1
Retiring System Alarms
To retire a system alarm, press the SEL pushbutton to execute an Alarm Cutoff (ACO). An ACO turns the alarm
off and replaces the
ALRM
message with an
ACO
message. The second part of the
ALRM
message, which defines
the cause of the alarm, remains. Both parts of the message remain until the alarm condition clears or another higher
priority alarm occurs.
xxx-DBER
DS1 Bit Error Rate 
The DS1 BER has exceeded the set 
threshold limits of approximately 10
-6
(xxx denotes either TUC or TUR. If TUC 
and TUR occur at the same time, then TUC 
displays.)
Select DIS for the DBER system option.
LOF
Loss of Frame
The DS1 input does not contain the ESF or 
SF frame pattern setting of the FRMG 
option.
Change FRMG option to AUTO or UNFR.
PRMF
Performance Report 
Messaging - Far End
Indicates H2TU-R PRM-FE BER threshold 
is exceeded.
Set DBER threshold to DIS.
PRMN
Performance Report 
Messaging - Near End
Indicates H2TU-R PRM-NE BER threshold 
is exceeded.
Set DBER threshold to DIS.
xxx-HBER
HDSL2 Block Error 
Rate 
The HDSL2 BER has exceeded the set 
threshold limits of 10
-6 
or 10
- 7
. (xxx 
denotes either TUC or TUR. If TUC and 
TUR occur at the same time, then TUC 
displays.)
Select NONE for the HBER system option.
xxx-MAL
Margin Alarm
The margin on the HDSL2 loop has 
dropped below the minimum threshold 
value set for the system. (xxx denotes 
either TUC or TUR. If TUC and TUR occur 
at the same time, then TUC displays.)
Set the Margin Alarm Threshold option to 
0 (zero).
xxx-LA
Loop Attenuation 
The attenuation on the HDSL2 loop has 
exceeded the maximum value set for the 
HDSL2 loop attenuation threshold. (xxx 
denotes either TUC or TUR. If TUC and 
TUR occur at the same time, then TUC 
displays.)
Set the HDSL2 Loop Attenuation 
Threshold option to 0 (zero).
(a) The message,
ALRM
, displays prior to any alarm message.
(b) Message displays repeatedly as long as the alarm condition exists and is not included in the priority order.
(c) Only these alarms assert the System Alarm bus on pins 20 and 21 of the card-edge connector if the ALM option is enabled.
(d) When the HDSL2 loop loses sync word (LOSW), a system alarm condition exists. However, since the H2TU-C-231 enters the
acquiring mode, the front-panel status LED flashes red, and the ACQ or SIG message displays instead of the ALRM message.
Table 15.
Front-Panel System Alarms Summary (Continued)
Front-Panel 
Message
 (a)
Alarm
Description
To Inhibit