Monitoring with an ASCII Terminal
Campus-REX RS Interface Card User Manual
6-3
2
Type 
then press 
. The Current System Status menu displays.
The Current System Status menu provides the following information:
Local Alarms indicates the current local alarm status
Remote Alarms indicates the current remote alarm status
Loopback indicates the current loopback status
Margin indicates the minimum (mn), current (cr), and maximum (mx) 
HDSL margin value, measured in dB, relative to the signal-to-noise ratio 
required for a Bit Error Rate (BER) of 10
-7
Pulse Attn indicates the decrease in amplitude of the transmitted signal 
as measured at the HDSL receiver
24 Hour ES indicates the number of errored seconds over the last 
24 hours
24 Hour UAS indicates the number of unavailable seconds over the last 
24 hours
Last Cleared indicates the date and time when the error counter was last 
cleared
1
ENTER
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:14:35
Local Unit ID:
Campus-REX Unit #34
Local I/F:
REX
Remote Unit ID: Campus-REX Unit #12
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
CURRENT SYSTEM STATUS
Local
Alarms:
Remote Alarms:
Loopback: None
HDSL-A
HDSL-B 
LOCAL
REMOTE
LOCAL
REMOTE 
--------
--------
--------
-------- 
mn/cr/mx
mn/cr/mx
mn/cr/mx
mn/cr/mx 
Margin (dB):
na/na/na
na/na/na
na/na/na
na/na/na 
Pulse Attn (dB):
00
00
00
00 
24 Hour ES:
00000
00000
00000
00000 
24 Hour UAS:
05671
00000
05671
00000 
Last Cleared:
None 
 
 
(U)pdate
(C)lear 
(R)eturn
(M)ain Menu 
ENTER CHOICE>