Testing
H4TU-C-319 List 1
September 12, 2003
 57
T
ESTING
 
WITH
 H4TU-R BERT G
ENERATOR
 
The H4TU-R BERT Generator screen allows transmission of an unframed test signal from the H4TU-R towards 
either the network (NET) or customer (CPE). Bit error rates are calculated and display on the Monitor screen.
1
Press 
 to logon remotely, then press 
 to select the Config menu (
2
Use the 
 and 
 arrow keys to select BERT Generator, then press 
.
3
Use the arrow keys to select an option, then press the 
 to cycle through the settings. Refer to 
 for a list of BERT Generator option settings. 
4
Press 
 to activate your choice.
5
To view BERT status, press 
 twice, then, using the 
 arrow key to select the Monitor menu, press 
6
Press 
 to return to the H4TU-C logon screen. You can exit the status screen while signal generation is active.
Figure 31.
H4TU-R BERT Generator Screen
The test pattern is sent out either from the line unit towards the network (toward NET) or from 
the remote unit towards the customer (toward CPE). Both test payloads must be looped back so 
they can be returned to the unit for BER detection. BER detection is performed in the line unit 
for both switch settings. 
Tests done towards the NET must be looped at some point external to the higher circuit. Tests 
done towards the CPE can either be looped back at some external point beyond the remote unit, 
or they can be looped back internally by a higher loopback, such as NREM. The test payload, 
for the CPE direction, also passes back and forth over the HDSL4 link to the H4TU-C before it is 
analyzed for errors.
R
C
ENTER
SPACEBAR
ENTER
ESC
ENTER
R
Monitor  Performance  Event Log  
Config
  Inventory  Report  Rlogon         Help
                                +----------------------+
                                | Standard Options ->  |
                                | ADC Options      ->  |
                                |
 BERT Generator   ->  
|
                                +--------------------------------------+
                                | BERT Signal Generator  : 
ENA
         |
                                | BERT Signal Pattern    : 1 in 8      |
                                | BERT Signal Linecode   : AMI         |
                                | BERT Signal Direction  : NET only    |
                                | BERT Interval          : Continuous  |
                                +--------------------------------------+
Use <Spacebar> to cycle through option settings and <Enter> to activate
 ID: xxxx—-xxxx—-xxxx--xxxx   02/01/2002 12:30:01   H4TU-R      System: OK