ADC HDU-409 Lists 1 Manuel D’Utilisation

Page de 44
Applications
 LTPH-UM-1234-01
6
April 30, 2003
 HDU-409 Lists 1, 2, and 3
A
PPLICATIONS
HiGain doublers operate with any number of other T1, Plain Old Telephone 
System (POTS), Digital Data Service (DDS), or other HiGain systems 
sharing the same cable binder group.
The HDU-409 can be used in two- to five-span circuits, depending on the 
models of the HLU and HRU being used with the doubler units and the power 
option chosen for the HRU. The number of doublers is equal to one less than 
the number of spans as shown in 
 lists the maximum number of HDU-409 doubler units that can be 
deployed according to which HLU and HRUs are used.
Each span can take up to 30 seconds to acquire HDSL 
synchronization. The total time to acquire end-to-end 
synchronization increases with the number of spans.
Table 3.
HDU-409 Circuit Ranges
HLU Model
Maximum Number of HDU-409 Doublers Per Circuit 
 (a)
(a) HRU-411 applications with Current-Customer Premises Equipment (I-CPE) ON are 
limited to single HDU-409 doubler circuits. The HRU-412 is limited to applications with 
one and two doublers only.
Line-Powered Remote
Locally-Powered Remote
I-CPE ON
I-CPE OFF
I-CPE ON
I-CPE OFF
HLU-388 List 2x, 
HLU-319 List 2x, 
HLU-231 List 3D, 
HLU-231 List 6D, 
HLU-232 List 1D
HLU-231 List 7x, 
HLU-431 List 1D
1
2
2
2
HLU-231 List 8D, 
HLU-319 List 5D, 
HLU-388 List 5D
HLU-231 List 8/List 8E, 
HLU-319 List 5/List 5E, 
HLU-388 List 5/List 5E
2
 (b)
(b) Requires HRU-402 or HRU-411.
2
 (c)
(c) Requires HRU-402 List 1 or List 3.