Adtran DSU 56 Manuel D’Utilisation

Page de 44
61200062L1-1
DSU 56/64 User Manual
3-1
Chapter 3
Test Modes
In addition to a self-test mode, the DSU 56/64 has other extensive 
test modes which are designed to help isolate problems to specific 
components of the communications circuit. These various test 
modes for the DSU 56/64 are initiated and terminated from the 
front panel using the 
S
ELECT
 and 
T
EST
 
buttons. 
SELF TEST
A self-test goes through the following cycle.
1.  When the DSU 56/64 is powered on, all LEDs on the front 
panel turn on simultaneously for approximately two seconds.
2.  After two seconds, all the LEDs turn off briefly. 
3.  The LEDs then cycle on in pairs with a fan-out pattern away 
from the 
A
LM
 indicator.
4.  Next, the LEDs cycle off in pairs with a fan-in pattern back 
towards the 
A
LM
 
indicator. 
These patterns are repeated four times for visual verification that 
all LEDs are functioning properly. 
At the completion of the LED test patterns, the 
PTRN LED 
is on, 
which indicates that the DTE with TP test is being performed.
If the test is successful, the 
E
RROR
 indicator does not turn on.
If the 
DTE 
WITH
 TP
 test fails, the 
RS
ALM
DTE
PTRN
, and 
E
RROR
 
indicators all flash.