MicroNet Technology MaxNAS Manuel D’Utilisation

Page de 79
MaxNAS Owner’s Manual
22
2.2.2 Expanding NAS volumes
To expand the network accessible space of a RAIDset to 
take  over  unused  space,  select  the  desired  RAIDSet  and 
click 
RAID Config
 on the RAID information screen (see above, 
section  2.2.)  The  RAID  Configuration  page  will  appear. 
Click 
Expand
 . 
The Expand RAID Space screen will appear. 
Select the new percentage of the resulting volume to be 
used  for  network  access.  Remaining  space  may  be  allocated  for  iSCSI  or  USB  target  mode. 
Click 
Expand
 
to complete the operation.
2.2.3 Appending disks to RAIDset
If  an  existing  RAIDset  does  not  use  all 
available  disk  mechanisms  it  may  be 
expanded  onto  the  unused  disk(s.)  To 
expand  an  existing  RAIDset,  Select  the 
desired  RAIDSet  and  click 
RAID Config
  on 
the RAID information screen (see above, 
section  2.2.)  The  RAID  Configuration 
page  will  appear.  Select  the  desired 
available disk(s) and click 
Append
2.2.4 Migrating RAIDSet
The MaxNAS allows RAIDsets to migrate 
on to unused disk modules as well as change the RAID level to fully utilize resources or to afford 
user flexibility. Online RAID level/stripe size migration can prove helpful during performance 
tuning activities as well as at the addition of physical disks to the MaxNAS. For example, in a 
system using two drives in RAID level 1, you could add capacity and retain fault tolerance by 
adding one drive. With the addition of third disk, you have the option of adding this disk to 
your existing RAID logical drive by migrating from RAID level 1 to 5. The result would be parity 
fault tolerance and double the available capacity without taking the system offline. To migrate 
a RAID 0, RAID 1, or RAID 5 volume, Select the desired RAIDSet and click 
RAID Config
 on the 
RAID information screen (see above, section 2.2.) The RAID Configuration page will appear. 
Click 
Migrate RAID
. A list of possible RAID migration configurations will be listed. Select the desired 
migration scheme and click 
OK
 The following is a table of possible RAID migrations:
 
  To
 
From
RAID 0
RAID 5
RAID 0
[RAID 0] HDDx2 to [RAID 0] HDDx3-5
[RAID 0] HDDx3 to [RAID 0] HDDx4-5
[RAID 0] HDDx4 to [RAID 0] HDDx5
[RAID 0] HDDx2 to [RAID 5] HDDx3-5
[RAID 0] HDDx3 to [RAID 5] HDDx4-5
[RAID 0] HDDx4 to [RAID 5] HDDx5
RAID 1
[RAID 1] HDDx2 to [RAID 0] HDDx2-5
[RAID 1] HDDx2 to [RAID 5] HDDx3-5
RAID 5
X
[RAID 5] HDDx3 to [RAID 5] HDDx4-5
[RAID 5] HDDx4 to [RAID 5] HDDx5
3-Administering the MaxNAS