Appendix B: RAID Level Comparison Table
RAID
Level
Description
Min. 
Drives
Max. 
Drives
Capacity Data 
Reliability
Data
Transfer Rate
I/O
Request Rates
Span Also known as disk spanning. Data 
is  distributed  sequentially  to  all 
drives. There is no data protection.
1
4
(N) 
Disks
No data protection
Same as a single disk same as a single disk
0
Also known as striping
Data  distributed  across  multiple 
drives  in  the  array  simultaneously. 
There is no data protection
1
4
(N) 
Disks
No data
Protection
Very High
Very High for
Both Reads and Writes
1
Also known as mirroring
All  data  replicated  on  N  Separated 
disks.  N  is  always  a  multiple  of  2. 
This  is  a  high  availability  Solution, 
but due to the 100% data duplication, 
it is also a costly solution.
2
4
1/(N )
Disks
Lower  than  RAID  6,  
Higher than RAID 5
Reads are higher
Than a single disk;
Writes similar to a sin-
gle disk
Reads  are  twice  faster 
than a single disk;
Write  are  similar  to  a 
single disk.
10
Also known as striped mirroring. Data 
and parity information is subdivided 
and distributed across all disks. This 
is  a  high  availability  Solution,  but 
due to the 100% data duplication, it 
is also a costly solution.
4
4
1/2 (N) 
Disks
Lower  than  RAID  6, 
higher than RAID 5
Reads  are  similar  to 
RAID 0
Writes  are  similar  to 
single disk
Reads  are  similar  to 
RAID 0
Writes are similar to sin-
gle disk
5
Also  known  Block-Interleaved 
distributed  Parity.  Data  and  parity 
information  is  subdivided  and 
distributed  across  all  disk.  Parity 
must  be  the  equal  to  the  smallest 
disk  capacity  in  the  array.  Parity 
information  normally  stored  on  a 
dedicated parity disk.
3
5
(N-1) 
Disks
Lower than RAID 1, 10
Higher  than  a  single 
drive
Reads are similar to
 RAID 0;
Writes  are  slower  than 
RAID 0
Reads are similar to
 RAID 0;
Writes are slower than a 
single disk.
6
Also  known  as  dual  parity.  Similar 
to  RAID  5,  but  does  two  different 
parity  computations  or  the  same 
computation on overlapping subsets 
of  the  data.  The  RAID  6  can  offer 
fault  tolerance  greater  that  RAID 
1  or  RAID  5  but  only  consumes 
the  capacity  of  2  disk  drives  for 
distributed  parity  data  reliability 
similar to RAID 0.
4
5
(N-2 
Disks)
Highest Reliability
Reads are similar to
RAID 0;
Writes  are  slower  than 
RAID 5
Reads are similar to
 RAID 0;
Writes are slower than a 
single disk.
B-RAID Level Comparison Table