ATLAS 830
P/N 1200780L1 (AC)/1200781L1 (DC)
For more detailed documentation, visit us online at  
Quick Start Guide
Quick Start Guide, 61200780L1-13A, August 2002
Technical Support 1-888-4ADTRAN (1-888-423-8726)
Copyright 
 2002 ADTRAN, All Rights Reserved
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
OFF
ON
CAUTION: FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
12A/125V
+
-
48 VDC,  6A
USE COPPER
CONDUCTORS ONLY
Network T1/PRI Ports
Optional DC
Power Supply 
P/N 1200229L1 
T1/PRI Monitor Jacks
 Alarm Relay Connection
Admin Interface
Option Module Slots
Power Supply Slot
Reviewing the Rear Panel Design
Admin Pinout
10/100BaseT Ethernet Pinout
PIN
NAME
DESCRIPTION
1
DCD
Data Carrier Detect (output)
2
RD
Receive Data (output)
3
TD
Transmit Data (input)
4
DTR
Data Terminal Ready (input)
5
SG
Signal Ground
6
DSR
Data Set Ready (output) -- not connected
7
RTS
Request to Send (input)
8
CTS
Clear to Send (output)
9
RI
Ring Indicate (output) -- not connected
PIN
NAME
DESCRIPTION
1
TX1
Transmit Positive
2
TX2
Transmit Negative
3
RX1
Receive Positive
4,5
Unused
6
RX2
Receive Negative
7, 8
Unused
Alarm Relay Connection Pinout
DC Power Supply Connection 
(Optional P/N 1200229L1)
PIN
NAME
DESCRIPTION
1
Normaly Closed (NC)
Opens when a selected alarm condition is present.
2
Normally Open (NO)
Closes when a selected alarm condition is present.
3
Common (COM)
Common connection between external circuitry 
and NC or NO terminal.
4
Chassis Ground (GND)
PIN
NAME
DESCRIPTION
1
+
Ground (GND)
2
-