Adtran 4120 Manuel D’Utilisation

Page de 205
Chapter 3.  Terminal Menu Operation and Structure
61200176L3-1
Express 4110/4120 User Manual
3-49
PPP/Max Failure
Write security: 3; Read security: 5
Due to the nature of PPP, configuration options may not be agreed upon 
between two PPP peers.  This value is the number of configuration-naks 
that should occur before an option is configuration-rejected.  This allows 
a connection to succeed that might otherwise fail. The possible values are 
5 (def), 10, 15 and 20.
Connection List/Dial Out
The dialing parameters for establishing this connection are defined under 
this menu.
Dial Out/Number 1
Write security: 3; Read security: 5
This is the first number used for dialing up this connection.
Dial Out/Number 2
Write security: 3; Read security: 5
This is the second number used for dialing a second B-channel when 
adding bandwidth.  If BACP/BAP is negotiated, this number is not nec-
essary.  If this number is not specified and BACP/BAP is not used, the 
Number 1
 number is re-dialed when adding bandwidth.
Dial Out/Call Type
Write security: 3; Read security: 5
The call type can be configured in four different ways:
Speech
 
Speech directs the call control software to request a 
Mu-law encoded speech circuit as the bearer capabil-
ity for the outgoing calls.  The speech option is used 
with an ISDN line configured for voice service.  In 
some areas, voice service costs  less than data ser-
vices.  A speech call type does not always guarantee 
an end-to-end digital connection with some local  and 
long distance carriers.