Emerson PMT1 Manuel D’Utilisation

Page de 128
Monitor:
 Start-up Display
PmT1 and PmE1 User’s Manual
10002367-02
8-4
START-UP DISPLAY
At power-up or after a reset, the monitor runs diagnostics and reports the results in the 
start-up display. The PmT1 and PmE1 displays have identical diagnostic reports.
Figure 8-1:
Monitor Start-up Display
Note:
The results of the power-up diagnostic tests are displayed at power-up or after a reset. A failed memory test 
could indicate a hardware malfunction that should be reported to our Technical Support department at
At power-up and reset, the monitor configures the board according to the contents of non-
volatile configuration memory. If the configuration indicates that an autoboot device has 
been selected, the monitor attempts to load an application program from the specified 
device. You can prevent the board from booting the OS if any of the power-up tests fail by 
setting the NVRAM configuration parameter HaltOnFailure (see 
Hardware
initialization
and power-up
diagnostic
reports
Monitor
command
prompt
Hello World !!!!!!!!!!!!!
  MPC860 and SMC are initialized
  Memory Size is 0x00400000
  860 Decrementer Test                   PASSED
  860 Time Base Timer Test               PASSED
  Print Hex Test, should = 89ABCDEF ?  89ABCDEF
  Power Up Memory Test
    Memory Test           at 0x00040000  PASSED
    Address Boundary Clear               PASSED
    All Memory Address Test ********
                                         PASSED
  BSS Zeroed
  Data Section Relocated
  Exception Vector Table Set to 0x0
  Stack has been initialized to 0x10000 - 8
  Monitor Cold Started
  Power Up EEPROM Test                   PASSED
  MPC860 Power Up Cache Test             PASSED
  PCI Bus Interface Initialized
Copyright Artesyn Communication Products, Inc., 2001
Created: Thu Jan 11 13:04:24 2001
===========
===========
===     ===
===     ===                    ======
===     ===                    ======
===========                      ==
===========  ===    ===          ==     ==
===          ====  ====          ==    ===
===          ==========          ==     ==
===          ==  ==  ==          ==     ==
===          ==      ==          ==     ==
PM/T1[Rev 2.6]
PM/Link (TM) Debug Monitor
Artesyn Communication Products,Inc.
Version Rev 2.6