Page de 128
Monitor:
 NVRAM Commands
PmT1 and PmE1 User’s Manual
10002367-02
8-14
Group ‘Console’
PortA(A, B)
Baud9600
ParityNone(Even, Odd, None, Force)
Data8-bits(5-Bits, 6-Bits, 7-Bits, 8-Bits)
StopBits2-bits(1-Bit, 2-Bits)
ChBaudOnBreakFalse(False, True)
RstOnBreakFalse(False, True)
[SP, CR to continue] or [E, e to Edit]
3
Press E to edit the group.
4
Press <cr> until the field you want to change is displayed.
5
Type a new value. For most fields, legal options are displayed in parentheses.
6
Press <ESC> or Q to quit the display.
7
Type nvupdate to save the new value or nvopen to cancel the change by reading the old 
value.
nvinit
is used to initialize the nonvolatile memory to the default state defined by the monitor. 
First nvinit clears the memory and then writes the Emerson and monitor data back to the 
EEPROM. 
Description:
nvinit sernum “revlev” ecolev writes
Caution:
nvinit clears any values you have changed from the default. Use nvinit only if the 
nonvolatile configuration data structures might be in an unknown state and you must 
return them to a known state. 
nvopen
reads and checks the monitor and Emerson-defined sections. If the nonvolatile sections are 
not valid, an error message is displayed.
Description:
nvopen
nvset
is used to modify the Emerson-defined and monitor-defined nonvolatile sections. 
sernum
serial number
revlev
revision level
ecolev
standard ECO level
writes
the number of writes to nonvolatile memory
!