Emerson 4620 Manuel D’Utilisation

Page de 52
Discovering Shelves and Domains
Using HPI-B
System Management Interface Based on HPI-B (Centellis 4620) User’s Guide (6806800D85A)
31
 
4.3.3.3
HPI Domain Events
Depending on the connection status, the Domain Connection sensor can throw events. The 
following table provides details. 
4.3.4
Discovering Shelves and Domains
As previously mentioned, one way to discover available domains is to use the Domain 
Reference Table. For further details, refer to the SAI-HPI-B.01.02 specification document. 
Table 4-7 Domain Connection Sensor
SaHpiSensorRecT
Value
Num
MOTHPI_SENSOR_NUM_DOMAIN_CONNEC
TION
Type
SAHPI_CHASSIS
Category
SAHPI_EC_AVAILABILITY
EventCtrl
SAHPI_SEC_PER_EVENT
Events
SAHPI_ES_ON_LINE | SAHPI_ES_OFF_LINE
Ignore
SAHPI_FALSE
DataFormat - ReadingFormats
SAHPI_SRF_EVENT_STATE
DataFormat - IsNumeric
SAHPI_FALSE
DataFormat - IsThreshold
SAHPI_FALSE
Oem
0
Table 4-8 Domain Connection Sensor Reading
SaHpiSensorReadingT
Value
ValuesPresent
SAHPI_SRF_EVENT_STATE
EventStatus - SensorStatus
SAHPI_SENSTAT_EVENTS_ENABLED | 
SAHPI_SENSTAT_SCAN_ENABLED
AssertEvents
SAHPI_ES_ON_LINE for a connection to a shelf
SAHPI_ES_OFF_LINE when there is no 
connection to a shelf
Table 4-9 Domain Connection Sensor Events
Event
Description
SAHPI_ES_OFF_LINE
No connection
SAHPI_ES_ON_LINE
Connection is established. Only now is the 
domain of the shelf accessible.