Functional Description 
6806800H60A  AMC-S402 Installation and Use  
 
10 
 
MUX
Power 
Regulator
| |  
|| |
| |||||
 || |
|||||||
||  | 
|||||||
| ||| 
   ||
 ||||||
||
80221 -
12-
04-
2007M
FB
 6635 
N
TC
Z
010
Power 
Regulator
MMC
 
Figure 5.  AMC-S402 Top Level Board Layout 
3.3  Serial Storage I/O Interfaces 
The AMC-S402 modules plug into ATCA carrier blades and uTCA backplanes which 
support AMC.3 storage signaling.  Port 2 is wired to the SAS primary port and Port 3 
is wired the SAS secondary port. 
Table 4 I/O Ports Available On AMC Connector 
AMC I/O 
Description 
Port 2 
3Gb SAS Receive and transmit pairs, Primary port 
Port 3 
3Gb SAS Receive and transmit pairs, Secondary port 
MMC device 
Serial IPMI management bus 
3.3.1  SAS Port Isolation Multiplexor Circuit 
The AMC-S402 includes SAS re-transmitter circuits that can be used to adjust or 
“wave-shape” the transmit signal characteristics driven out the AMC finger 
connections (storage signaling ports 2 and 3).  At manufacturing time, this circuit is 
pre-set to values that are optimal for the majority of deployments.   
Programmable parameters include: 
  transmit pre-emphasis (five levels)  
  receiver equalization (three levels) 
  Transmit output swing to support SAS up to 1600mV 
Tools are available to adjust these circuits to accommodate atypical backplane or 
cable situations.  Please contact your Emerson applications engineer if you feel your 
deployment will require different settings.