Emerson XWEB5000 Manuel D’Utilisation

Page de 48
 
1592010860 XWEB5000 stp GB r1.1 2012.06.22.doc                                     XWEB5000 
7/48 
 
 
Figure 2 
 
 
RS485  NETWORK:  always  use  the  indicated  polarity;  total  length 
shall  not  exceed  1000m;  electric  line  shall  not  spit  or  use  star-
connections;  avoid  proximity  of  electric  power  sources;  usage  of 
shielded  cable.  Its  wires  shall  be  0.5  mm
2
 minimal  section.  Shield 
shall not be connected. Belden 8772 cables are reccomended. 
Connect  a  terminal  line  resistor  (120  Ohm,  1/4  W)  on  the  most 
distant  device.  Resistor  shall  connect  +  and  –  of  its  serial 
connector. 
 
Technical details 
Power supply 
110 .. 230V ; 0,40A ; 50/60Hz 
 
60W  
Temperature/Humidity 
0 .. 40°C  20.. 85 % R.H. 
Digital outputs (relays) 
2 relays 8A 250V N.O. 
1 relay 8A 250V double touch 
Serial ports 
1 RS-232 port 
1 RS-485 optoinsuled 
USB port 
2 standard connection A type ports 
Internal modem (if available) 
Socket modem, PSTN V.34/33.6K 
Electrical safeguard normative 
EN60950 
Electromagnetc compatibility normative 
EN55022; EN55024; EN61000