ICOM IC-FR5100 Manuel D’Utilisation

Page de 16
6
10
ABOUT CE
INSTALLATION NOTES
•  Compliance of base station transmitter installa-
tions with EN50385
The installation of this equipment and it’s associated 
antenna should be made in such a manner as to re-
spect the EC recommended electromagnetic (EM) 
field exposure limits. (1999/519/EC)
In order not to exceed these exposure limits it is nec-
essary to determine the ‘Compliance Boundary,’ that 
means the volume within which the EM field radiated 
by the transmitter/antenna installation may exceed the 
1999/519/EC limits. You will then need to ensure that 
members of the general public do not have access 
within this area. The actual Compliance Boundary for 
this repeater will be totally dependant on the antenna, 
feeder, RF amplifier and other passive or active de-
vices used in the installation.
The RF output power of this repeater is 25 watts.
The figures contained in this guide are based on the 
recommended limits for the general public and are 
obtained by ‘worst case’ numerical analysis. For a de-
finitive evaluation of any given installation, measure-
ments should be made with an EM field meter and a 
broadband calibrated probe.
• Installation
The antenna should be installed as high as possible 
for maximum efficiency and minimum EM field at 
ground-level. The evaluation of radiated field should 
take into account any additional RF amplifiers used, 
any loss in the antenna feeder cable and the gain of 
the antenna used as well as its polar radiation pattern.
If there are any objects or structures larger than 
half a wavelength close to the antenna, or within the 
clearance distances specified, then these can cause 
reflections which will have an effect on the overall ra-
diation pattern.
For any installation you need to consider ‘height clear-
ance’ (i.e. the height above any place where persons 
may have access) and ‘front clearance’ (i.e. the dis-
tance in front of the antenna where the radiated field 
may exceed the recommended limits). Normally with 
an antenna installed on a reasonably high mast or 
tower, there will not be any access point directly in 
front but care should be exercised when there are 
other buildings higher than the antenna within the vi-
cinity.
•  Installation with a vertical type antenna at VHF-
UHF
You need to consider the distances between the an-
tenna and any point where persons may have access. 
Allowing an average height of 1.8 m for a person in 
the vicinity of the antenna the clearance distances 
can be evaluated as follows. For the antenna a for-
ward gain of 1.6 and downward gain of unity has been 
assumed.
 
Power 
EIRP  Distance
  Height 
Front 
 
 
 
 
clearance  clearance
  1 watt 
1.6 watts  0.32 m 
2.1 m 
0.4 m
  10 watts 
16 watts 
1 m 
2.8 m 
1.3 m
  25 watts 
40 watts 
1.6 m 
3.4 m 
2 m
 100 watts  160 watts 
3.2 m 
5 m 
4 m
  1 kW  1600 watts 
10 m 
12 m 
13 m
• Installation with a yagi or directive type antenna
Exposure distance assumes that the predominant ra-
diation pattern is forwards and that radiation vertically 
downwards is at unity gain (sidelobe suppression is 
equal to main lobe gain). This is true of almost every 
gain antenna today. Exposed persons are assumed 
to be beneath the antenna array and have a typical 
height of 1.8 m.
The figures assume the worst case emission of con-
stant carrier.
RF power  Clearance heights by frequency band
  Watts 
10–2 m 
70 cm 
23 cm
 
13 cm  
 
 
 
 
 
and above
 
2.1 m 
2 m 
2 m 
2 m
  10 
2.8 m 
2.7 m 
2.5 m 
2.3 m
  25 
3.4 m 
3.3 m 
2.7 m 
2.5 m
  100 
5 m 
4.7 m 
3.6 m 
3.2 m
 1000 
12 m  11.5 m 
7.3 m 
6.3 m
  EIRP 
Forward clearance, EIRP by frequency band
  Watts 
10–2 m 
70 cm 
23 cm
 
13 cm  
 
 
 
 
 
and above
 
100 
2 m 
2 m 
1.1 m 
0.7 m
 
1000 
6.5 m 
6 m 
3.5 m 
3 m
  10,000 
20 m 
18 m 
11 m 
7 m
 100,000 
65 m 
60 m 
35 m 
29 m