RAD Data comm ASMi-52 Manuel D’Utilisation

Page de 186
Appendix A  Interface Connector Specifications 
Installation and Operation Manual 
A-4 
CONTROL Connector 
ASMi-52 Ver. 2.5 
A.2 CONTROL Connector 
The control terminal interface terminates in a V.24/RS-232 9-pin D-type female 
connector that can be configured as DCE or DTE (see the 
Selecting the Control 
Port Interface
 section in Chapter 4). 
Table A-4
 lists the CONTROL connector pin 
assignments. 
Table A-5
 describes the control signal direction. 
Table A-4.  CONTROL Connector Pinout 
Pin  
Function 
Data Carrier Detect (DCD) 
Receive Data (RD) 
Transmit Data (TD) 
Data Terminal Ready (DTR) 
5 Ground 
(GND) 
Data Set Ready (DSR) 
Request To Send (RTS) 
Clear To Send (CTS) 
Ring Indicator (RI) 
Table A-5.  CONTROL Connector Signal Direction 
Interface Type 
Control Signal 
DCE DTE 
CTS Out  Not 
Used 
DCD Out  Out 
DSR Out  Out 
DTR In 
In 
RI Not 
Used 
In 
RTS In 
In 
 
When connected and turned on, the terminal sets the DTR line ON (active) to gain 
control over ASMi-52 and starts a configuration or monitoring session. 
 
When connecting a dial-out modem to the CONTROL port for the alarm 
reporting, a cross cable must be used. 
Table A-6
 provides the pinout of a typical 
cross cable with two male DB-9 connectors. 
Note