RAD Data comm ASMi-52 Manuel D’Utilisation

Page de 186
Chapter 1  Introduction 
Installation and Operation Manual 
1-4 Overview
 
ASMi-52 Ver. 2.5 
Features 
Functionality 
ASMi-52 can be configured to operate in a CO (central office) or CPE (customer 
premises equipment) mode. 
Line Interface 
ASMi-52 extends the range of data transmission over 2/4-wire lines up to 7.0 km 
(4.3 miles), by employing SHDSL TC-PAM technology. ASMi-52 operation 
complies with the requirements of the ITU-T G.991.2 standard. In addition, 4-wire 
ASMi-52 units can be configured to operate over 2-wire lines. 
Table 1-1
 lists typical ASMi-52 ranges over 2/4-wire 26 AWG line. 
Table 1-1.  Typical Ranges (26 AWG) 
Data Rate 
2-wire 
4-wire 
[kbps] 
[km] 
[miles] 
[km] 
[miles] 
64 7.5 
4.6 
— 
— 
128 
7.0 4.3 7.1 4.4 
256 
6.7 4.1 6.8 4.2 
384 
6.5 4.0 6.7 4.1 
512 
6.3 3.9 6.6 4.1 
1024 
5.3 3.3 6.0 3.7 
1536 
5.0 3.1 5.6 3.5 
2048 
4.5 2.8 4.7 2.9 
2304 
4.2 2.6 4.5 2.8 
4096 – 
– 
3.7 
2.3 
4608 – 
– 
3.0 
1.8 
 
The typical ranges are based on error-free lab tests without noise. 
ASMi-52CD/4W operates at data rates up to 4608 kbps, depending on internal or 
external clock. 
 
Note