RAD Data comm ASMi-52 Manuel D’Utilisation

Page de 186
Chapter 1  Introduction 
Installation and Operation Manual 
1-12 Technical 
Specifications
 
ASMi-52 Ver. 2.5 
Internal oscillator
 – Serves as a source of internal clock for the ASMi-52 unit. 
Modem glue logic module
 – Processes the data from/to the SHDSL interface 
module. 
SHDSL line interface
 – Translates the received and transmitted data from the line 
to the DTE interface. 
Power supply
 – Provides 2.5V, 3.3V, 5V and -5V to the ASMi-52 internal 
elements. 
CPU
 – Controls the ASMi-52 operation. 
10/100BaseT management port
 – Provides LAN connection to the SNMP 
management station or Telnet host. 
LEDs and terminal interface
 – Provides modem status information via LED 
indicators on the front panel, and communicates with the 
supervisory terminal.  
1.4 Technical 
Specifications 
Line Interface 
Type 
2/4-wire unconditioned dedicated line (twisted pair) 
 
Line Coding 
TC-PAM 
 
Range 
See 
Table 1-1
 
 
Impedance 
135Ω 
 
Connectors 
•  ASMi-52: RJ-45 
•  ASMi-52CD: Two RJ-45 
 
Standard 
ITU-T 991.2, ETSI 101 524 
 
E1 Jitter 
Performance 
As per ITU G.823 
 
Protection 
ITU K.21, UL1950 
DTE Interface 
Data Rate 
Depends on the DTE/line interface type and clock mode 
(see 
Table 1-2 
and
 Table 1-3
) 
•  2-wire (external clock): 64–2304 kbps, 
2-wire (internal clock): 64–2048, 2304 kbps 
•  4-wire (external clock): 64–4608 kbps, 
4-wire (internal clock): 64–4096, 4608 kbps 
•  ASMi-52CD/4W: 
(external clock): 128-4608 kbps 
(internal clock): 128-4096, 4608 kbps 
 
Coding 
•  E1: HDB3 
•  T1: B8ZS or AMI 
 
Line Impedance 
•  E1: 120Ω, balanced  
75Ω, unbalanced (via adapter cable)