Chapter 4  Configuration 
Installation and Operation Manual 
4-34 
Configuring the Physical Ports
 
ASMi-52 Ver. 2.5 
•  The Unit Identical Set is permanently set to Yes, the parameters are copied to 
the remote unit. 
If the Frame Mode is not G732S: 
•  The Unit Identical setting can be set to Yes or No when the local modem is 
configured as CO and both modems are E1. 
•  If the Unit identical set is Yes, then the Sync Mode, TSA and Idle Code are 
automatically configured in the remote unit if the following conditions are 
met: 
 
If the local ASMi-52 is defined as CO. 
 
If the local ASMi-52 is defined as CPE and the remote unit is not an E1 
modem. 
 
In the remote ASMi-52 if the local is defined as CPE and it is not an E1 
modem. 
•  If the Unit identical set is No, then the Sync Mode, TSA and Idle Code are 
configurable as follows: 
 
Local ASMi-52 in any configuration. 
 
Remote ASMi-52 if the local is defined as CO. 
 
To match remote unit settings with local unit settings: 
1.  From the E1 Configuration menu, select Local/Remote Port (Main menu > 
Configuration > E1 Configuration > E1 Local/Remote Port). 
The E1 Local/Remote Port is displayed. 
2.  From the E1 Local/Remote Port menu, select Units Identical Setting
The Units Identical Setting value changes to YES
3.  Save the changes. 
Configuring the T1 Interface 
ASMi-52 units with T1 interface require configuration of the following parameters: 
•  Framing mode:  
 
Unframed
 – Stream of bits at 1.544 Mbps 
 
ESF 
– 24 frames per multi-frame 
 
SF
 - 12 frames per multi-frame 
•  Line coding:  
 
B8ZS 
– B8ZS coding 
 
AMI 
– AMI coding 
•  Receive gain (sensitivity of the receive equalizer):  
 
Long 
– -36 dB 
 
Short 
– 15 dB 
•  Interface:  
 
DSU 
– DSU interface 
 
CSU  
– CSU interface