RAD Data comm MBE10-8D Manuel D’Utilisation

Page de 58
 
 
 A-1 
Appendix A 
Pin Assignment 
This appendix: 
•  Provides information about the various interfaces and cable connections 
supported by MBE. 
Table A-1.  Interface Signal List (Female Connectors) 
 
Signal Function  Source 
V.24/ 
RS-232 
DB-25 
(Female) 
V.35* 
34-PIN 
(Female) 
EIA-530 
DB-25 
(Female) 
V.36/ 
RS-449** 
DB-37 
(Female) 
X.21***  
DB-15 
(Female) 
Description 
 
 
 
 
Pin Circuit 
Pin Circuit  Pin Circuit  Pin Circuit   
Protective 
Ground 
COMMON  1 
A Frame    
101 
1 1 1 
-- 
 [SHIELD] 
Chassis ground. May 
be isolated from Signal 
Ground. 
Ground 
Signal 
Ground 
COMMON 7 
B Signal 102 
GND 
 
7 AB 
19 
SG 8 
-- 
 [GND] 
Common Signal and 
DC power supply 
ground 
Transmitted Data 
DTE 
S TD(B)  103 
P TD(A)  103 
 
 
2 BA(A) 
14 BA(B) 
 
 
 2 
 
T(A) 
9 T(B) 
    [TRANSMIT] 
Serial data output 
from unit. The data 
transitions must occur 
on the rising edge of 
the transmit clock. 
Data 
Received Data 
DCE 
R RD(A)  104 
T RD(B)  104 
 
 
 6 
 
RD(A) 
24 RD(B) 
4  
R(A) 
11   R(B) 
 [RECEIVE] 
Serial data input to the 
unit. The data 
transitions occur on 
the rising edge of the 
clock. 
Request to Send 
DTE 
C RTS 
105 
CA(A) 
19 CA(B) 
7 RS(A) 
25 RS(B) 
3  
C(A) 
10   C(B) 
    [CONTROL] 
ON from the unit 
upon completion of 
self-test 
Clear To Send 
DCE 
D CTS 
106 
CB(A) 
13 CB(B) 
9 CS(A) 
27 CS(B) 
-- 
Unit expects CTS ON 
Data Set Ready 
DCE 
E DSR 
107 
CC(A) 
22 CC(B) 
11 DM(A) 
29 DM(B) 
 
 
-- Not 
used 
Data Terminal 
Ready 
DTE 20  H 
DTR 
108 
20 
CD(A) 
23 CD(A) 
12 TR(A) 
30 TR(B) 
-- 
ON when unit is ready
to transmit or receive 
data 
Control 
Carrier Detect 
DCE 
F DCD  109 
CF(A) 
10 CF(B) 
 
 
13 RR(A) 
31 RR(B) 
5  
I(A) 
12  
I(B) 
   [INDICATION] 
Unit expects DCD ON 
Order from: Cutter Networks