RAD Data comm IPmux-16 Manuel D’Utilisation

Page de 99
Chapter 1  Introduction 
IPmux-16 Installation and Operation Manual 
1-8  Functional Description
 
 
•  Adaptive: In this mode, the E1 or T1 Tx clock is regenerated using the 
Adaptive method. In this method, the fill level of the buffer receiving packets is 
monitored. If the buffer begins to overfill, the regenerated clock frequency 
increases to avoid overflow. If the buffer begins to empty, the clock decreases 
to avoid underflow. 
•  Internal Clock: In this mode, the Transmit (Tx) clock is received from an 
internal oscillator. This mode is useful for testing and diagnostic purposes. 
Each of the clocks must be configured correctly on both the Receive and Transmit 
ends to ensure proper operation and prevent pattern slips. 
The following paragraphs describe typical timing schemes and their correct timing 
mode settings in order to achieve end-to-end synchronization.  
External Network Timing 
When an external network is used to synchronize the E1/T1 devices, all the 
IPmux-16 units should be configured to work in loopback mode (see the following 
illustration). This topology enables any-to-any connectivity; as in the following 
illustration, all three IPmux-16s have direct E1/T1 connectivity. In this timing 
configuration both mesh and star bundle connection topologies are supported. 
IP over 
Ethernet
IPmux-16
E1/T1 Device
E1/T1
E1/T1
Clock from External Distribution Network
LBT Mode
IPmux-16
E1/T1 Device
E1/T1
E1/T1
LBT Mode
IPmux-16
E1/T1 Device
E1/T1
E1/T1
LBT Mode
 
Figure 1-6.  IPmux-16 in Loopback Timing Mode 
Single Source Clock Network 
When a common clock is not available on all the ends of the network: 
•  E1/T1 Device Configuration: 
One of the E1/T1 devices connected to the IPmux-16 should work as the 
master clock while the others work in loopback timing. 
•  IPmux-16 Configuration
The IPmux-16 E1/T1 ports connected to the master clock E1/T1 device work in 
loopback timing, while the far-end IPmux-16s work in Adaptive mode.