RAD Data comm IPmux-16 Manuel D’Utilisation

Page de 99
IPmux-16 Installation and Operation Manual 
Chapter 3  Operation 
 
Configuring IPmux-16 
3-27 
 
When “unframed” mode is selected, the Idle Code, Signaling Mode, Cond Data 
Pattern and Cond CAS Pattern fields are not present. 
When CAS Disabled is selected, the Cond CAS Pattern field is not present. 
 
➤ 
To change the source of the transmit clock: 
•  Type 1 and press the <Spacebar> on your keyboard to toggle between  
Adaptive/Loopback/Internal/External. 
Adaptive: Adaptive 
clock 
regeneration 
Loopback: 
The E1 recovered receive clock is used as the transmit clock. 
Internal: 
A local clock source is used. 
Default value: Adaptive 
➤ 
To change the Loopback State setting: 
Refer to Chapter 4 for detailed instructions on loopback tests. 
➤ 
To change the RX Sensitivity setting: 
•  Type 3 and press the <Spacebar> on your keyboard to toggle between 
–10 dB / –32 dB. This setting determines the maximum attenuation of the 
receive signal that can be compensated for by the interface receive path. 
Default value: E1: -10 dB 
➤ 
To change the Line Type setting: 
•  Type 4 and press the <Spacebar> on your keyboard to toggle between CRC4 
Enable / CRC4 Disable / UNFRAMED. This setting determines the framing 
mode and operation mode for each configuration. 
−   Unframed:  Framer will be configured to pass through mode and the 
operation mode will be set to Unframed (see Chapter 1, section 1.3). 
−   CRC4 Enable:  Framer will be configured to CRC4 MF mode. Operation 
mode will be set by Signaling Mode field #6 to either Fractional or 
Fractional with CAS (see Chapter 1, section 1.3). 
−   CRC4 Disable:  CRC4 MF mode is disabled. Operation mode will be set by 
Signaling Mode field #6 to either Fractional or Fractional with CAS (see 
Chapter 1, section 1.3). 
 Default 
value: 
 CRC4 enabled
 
 
Changing the Line Type setting will delete all connections. 
 
➤ 
To determine the idle code inserted into unused time slots by IPmux-16-E1 at 
the transmit path towards E1 equipment: 
•  Type 5 (Idle code) and enter a new value.  
(This field will not appear if “unframed” is selected in the Line Type field.)  
Range:  00-FF 
Default value: 7E 
Note 