RAD Data comm IPmux-16 Manuel D’Utilisation

Page de 99
Chapter 3  Operation 
IPmux-16 Installation and Operation Manual 
3-32 Configuring IPmux-16
 
 
➤ 
To determine the 2 or 4 bit code applied to AB(D4) or ABCD (ESF) bits when 
fault conditions occur:  
•  Type B (Cond CAS (ABCD) pattern). 
The ABCD conditioning pattern can be applied toward the IP path when loss 
of signal, loss of frame or AIS detected at the T1 line. Conditioning pattern can 
also be applied toward the T1 line when packet receive buffer overrun or 
under run occur. 
(This field will not appear if “unframed” is selected in the Channel Type field.)  
Range:  1–F  
Default value:  1 
➤ 
To determine the 2 or 4 bit code applied (during the first 2.5 seconds) to 
AB(D4) or ABCD (ESF) bits (relevant in CAS mode only) when fault conditions 
occur: 
•  Type C (Cond. CAS first 2.5 sec pattern). This code will be inserted in the first 
2.5 seconds and then the code specified in ‘Cond. CAS (ABCD) pattern’ will 
be applied. ABCD conditioning pattern can be applied toward the IP path 
when loss of signal, loss of frame or AIS detected at the T1 line. A conditioning 
pattern can also be applied toward the T1 line when packet receive buffer 
overrun or underrun occur. When configuring FF to this function, this 
parameter will be ignored and the CAS pattern that will be applied in the first 
2.5 seconds will be the same as defined in ‘ Cond. CAS (ABCD) pattern’.  
This field will not appear if “unframed” is selected in the Line Type field or if 
CAS Disable is selected. 
Range:  0–F (ESF), 0–3(D4), FF 
Default value: FF 
Time Slots Configuration 
Main Menu 
↓  
2. Configuration 
↓  
3. Time Slots
 
Configuration 
➤ 
To configure the time slots: 
•  Type 3 (Time Slots Configuration) in the Configuration menu. 
This configuration defines the bundles you want to send. Up to 31/24 
bundles can be sent for each E1/T1 (see Chapter 1, Functional Description 