RAD Data comm MBE10-1D Manuel D’Utilisation

Page de 58
MBE Family Installation and Operation Manual 
Chapter 1  Introduction 
 
Functional Description 
1-9 
Bridge Mode Filtering Block (MBE10-8 and MBE10-8D only) 
In addition to MBE10-1 functions, MBE10-8 and MBE10-8D have a filtering block. 
The filtering block in the local MBE compares the destination address of every 
frame transmitted on the main LAN to the table of remote workstation addresses. 
The result of the filtering block comparison generates a copy/not copy frame 
command for the LAN processor.  
If a frame is addressed to one of the remote workstations, the local MBE forwards 
this frame to the link. The remote MBE compares the destination address of every 
frame transmitted on the remote LAN with the remote workstation address table. 
All frames in the remote LAN, containing destination addresses not included in the 
remote workstation address table, will be forwarded to the link by the remote 
MBE. 
If the frame destination address is of the broadcast or multicast type, the filtering 
block compares the source address of the frame to the remote workstation address 
table. This source address check results in a copy/not copy command for the LAN 
processor. 
Link Interface 
The link interface provides the physical connection to either V.24/RS-232, V.35, 
RS-530, V.36, 4W, X.21, ISDN or DDS links. The 4W interface provides an 
internal short range modem with internal clock. DCE mode is provided for bench 
testing by V.24 and V.35 link interfaces. In DCE mode, the internal clock rate can 
be adjusted by selecting options from the internal clock rate setup menu (see 
"Internal Clock Rate Setup" 
in the 
LAN RANger Series Configuration Guide
).  
Main Processor and Communication Processor 
The main processor controls the LAN and communication processors. It performs 
buffer management and transfers the frames received from the LAN for 
transmission to the link and vice versa.  
The communication processor provides an HDLC link for transmission and 
reception of frames to the main processor. Error checks and retransmissions ensure 
an error-free link. 
Power Supply 
The MBE power supply provides required operating voltages. The power supply 
input ranges between 100 VAC to 240 VAC. 
Asynchronous Control Port  
The RJ-45 control port provides setup, configuration, and monitoring and 
download interface using an asynchronous ASCII terminal as a terminal emulator. 
Management 
Quick setup and configuration is performed via a terminal emulator attached to 
the control port, or via TELNET access to the device over the LAN or WAN. 
An SNMP agent provides in-band or out-of-band management by RADview or by 
any other standard SNMP management station. 
Software downloading is available through the control port, using XMODEM, and 
through the LAN or WAN using TFTP. Parameter file downloading and uploading 
is available through the LAN or WAN using TFTP. 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com