Trango Broadband 5010 Manuel D’Utilisation

Page de 45
SNMP 
Atlas SNMP Support 
 
Trango Broadband Wireless — Atlas5010 
page 31 
 
 
Chapter 5 SNMP 
Atlas SNMP Support 
The Atlas supports SNMP (Simple Network Management Protocol). Network management consists of the following 3 
categories: configuration, Link and Association monitoring and Alarms. Besides this proprietary Management 
Information Base (MIB) the Atlas also supports a large part of the MIB-II OIDs.  
 
Review the Trango MIB (TRANGO-P5M-MIB.mib) available on our website for the complete listing of all MIB objects 
available. 
 
These capabilities allow the system administrator to provide superior service through higher network accessibility and 
integrated performance monitoring. 
 
Depending on your Network Node Manager (NNM) it may be necessary to append a “.0” onto the end of each of the 
OIDs listed below for proper operation. 
 
Objects for Configuration                  Name 
 
                 
Description              
1.3.6.1.4.1.5454.1.40.1.1.1 
verUnitType 
 
 
Returns radios unit type  
(0 = RU, 1= MU) 
1.3.6.1.4.1.5454.1.40.1.8.3 sysswAutoScanMUSignal 
Returns value of Auto Scan switch  
(0 = off,1 = on) 
1.3.6.1.4.1.5454.1.40.1.3 sysDefaultOpmode 
 
Returns defaultOpmode setting 
        (0 
off,1 
on) 
1.3.6.1.4.1.5454.1.40.1.4 
sysCurrentOpmode 
 
Returns current opmode setting 
        (0 
off,1 
on) 
1.3.6.1.4.1.5454.1.40.1.5 
sysActivateOpmode 
 
Turns opmode on 
1.3.6.1.4.1.5454.1.40.1.13.1 
sysipconfigIpAddress   
Sets IP address 
1.3.6.1.4.1.5454.1.40.1.13.2 sysipconfigSubnet   
Sets 
subnet 
1.3.6.1.4.1.5454.1.40.1.13.3 
sysipconfigDefaultGateway 
Set default gateway 
1.3.6.1.4.1.5454.1.40.1.13.4 
sysipconfigChange 
 
Activates IP address change 
1.3.6.1.4.1.5454.1.40.2.1 rfPeerDeviceID 
  Configure 
PeerID 
1.3.6.1.4.1.5454.1.40.2.2 
rfActiveChannel 
  Displays 
current 
channel 
1.3.6.1.4.1.5454.1.40.2.3 rfActivePolarization 
 
Displays current antenna polarization 
1.3.6.1.4.1.5454.1.40.2.4 rfSpeed 
   Displays 
current 
Speed 
setting 
1.3.6.1.4.1.5454.1.40.2.5 rfTxPower 
 
 
Displays current transmit power (dBm) 
1.3.6.1.4.1.5454.1.40.1.14 
sysRemarks 
  Display 
radios 
remarks   
 
Objects for Link and Association Monitoring 
1.3.6.1.4.1.5454.1.40.2.12 
rfRSSI 
   Displays 
RSSI 
value 
(dBm) 
1.3.6.1.4.1.5454.1.40.2.13 
rfAssociated 
  Displays current association status 
        (0 
disassociated,1 
associated) 
1.3.6.1.4.1.5454.1.40.3.2 
ruReboot   Reboots 
RU 
1.3.6.1.4.1.5454.1.40.3.3 
ruDistance 
  Displays 
current 
ru 
distance 
Objects for Bandwidth Monitoring 
1.3.6.1.4.1.5454.1.40.1.9.1 systrafficEthInOctets 
 
Displays Ethernet in (bytes) 
1.3.6.1.4.1.5454.1.40.1.9.2 
systrafficEthOutOctets   
Displays Ethernet out (bytes) 
1.3.6.1.4.1.5454.1.40.1.9.3 
systrafficRfInOctets 
 
Displays RF in (bytes) 
1.3.6.1.4.1.5454.1.40.1.9.4 
systrafficRfOutOctets   
Displays RF out (bytes) 
Objects for Alarm Monitoring 
1.3.6.1.4.1.5454.1.40.3.4.1.1 trapTrapDstEntry 
1.3.6.1.4.1.5454.1.40.3.4.1.2 trapTrapDstEnabling  
Enable/Disable 
trap 
1.3.6.1.4.1.5454.1.40.3.4.2         trapTrapIpAddress                     Set destination trap IP 
1.3.6.1.4.1.5454.1.40.3.4.3 
trapTrapCommStr 
 
Set trap community string