System Administrator Screens
312353B
33
System Configuration ______________________________________
There are three sections of the System Configuration screen:  General system-wide default settings, transceiver set-
tings, and PC client settings (F
IG
. 63).
The System Configuration setup must be performed prior to defining all other Matrix system setup parame-
ters.
 
To change any of the settings listed for system configu-
ration, click Modify.
Security Level (Global Setting)
The security level is the global security setting for all 
meters in the system, The default is System Monitoring. 
PIN code and Parts Room Authorization Security are 
other options on the pull down menu. This security 
choice can be changed on a meter-to-meter basis if 
desired (F
IG
. 64).
1.
Click Security Level Drop Down Box and select 
from the list. 
System Monitoring - anyone can dispense oil, but 
the dispense information will be communicated to 
the PC.
PIN Code Required - the operator must enter a 
user-specific 4-digit numeric code into the meter to 
have authorization to dispense.
Parts Room Authorization - the operator selects 
authorization to dispense at the meter. This requires 
someone in the Parts Room to authorize the dis-
pense at the Matrix PC.
System Emergency Code (F
IG
. 64)
The System Emergency Code is used to bypass PIN 
Code or Parts Room Authorization security features 
should the communication link to the Matrix PC stop (i.e. 
computer failure, power outage).
2.
Type in a four digit system emergency code number. 
This number is used at the meter to override all meter 
programming should there be a loss of RF signal. 
This allows the operator to continue dispensing fluids 
even though the meter is not receiving an RF signal.
If the system emergency code is used to over-
ride the meter program, the meter must be pro-
grammed again using the Matrix PC software 
once the RF signal has been restored.