Carrier Access Access Navigator Manuel D’Utilisation

Page de 704
Access Navigator - Release 1.8
August 2003
18-141
 
CLI Language Reference
CLI Command List
Message:
Settings for DS1 9:
  Circuit ID:              CA DS1# 9
  Up/Down:                 DOWN
  Framing:                 ESF
  Line Coding:             B8ZS
  Type:                    DROP
  Clock Source:            NORMAL
  Line Build Out:          CSU ATTEN FOR -15dB
  Loop Code Detection:     ON
  Loop Back:               OFF
  Line Termination ID:     0 (for switch DS1s only)
  Remote Device MGMT:      CA IP 192.168.201.1  
  PPHONE Call Connection:  Enabled
  FDL Type:                None
  Send Code:               NONE
  Performance Thresholds:      15 min.    1 hour     1 day
                              --------   -------    ------
  unavailable seconds:               0         0         0
  severely errored seconds:          0         0         0
  errored seconds:                   0         0         0
  sev. errored frame seconds:        0         0         0
  degraded minutes:                  0         0         0
  linecode violations:               0         0         0
NOTE:  
The Performance Thresholds are threshold values, not error counts.
Description:
Item
Description
Circuit ID
Circuit identifier set by user for the DS1 number.
Up/Down
Link service status: UP, DOWN.
Framing
D4 (SF), ESF, SLC96 (S4).
Line Coding
AMI, B8ZS.
Type
DROP, GROOM, SWITCH. Switch type appears only with GR-
303 option.
Clock Source
NORMAL, LOOP.
Line Build Out
DSX-1 equalization (ft.), CSU attenuation (dB).
Loop Code Detection
ON, OFF.
Loop Back
OFF, LINE, PAYLOAD.
Line Termination ID
Line termination identifier, 1 to 28, set by user (used by GR-303 
only.
Remote Device MGMT
NONE, CAFDL, CAIP <ipaddress>, DS1 <n>.