DENOISER SNR2000
We recommend the following control settings:
Controls
Settings
IN/OUT switch
IN
EXPANDER switch
IN
THRESHOLD control
-50 dBu
RELEASE control
2 seconds
RATIO control
3:1
FILTER switch
IN
SENSITIVITY switch
-30 dBu
AUTO switch
IN
Tab. 3.2: Initial settings of the DENOISER
3.2 Studio applications
3.2.1 Noise reduction during playback
For this standard application, the DENOISER is inserted after the master or multitrack machine, i.e. between
tape machine and mixer (or amplifier). A cassette recorder or similar machine may also be the signal source.
Fig. 3.1: Noise reduction during playback
1. Set up your equipment as usual, while bypassing your DENOISER.
2. Turn on the BEHRINGER DENOISER and adjust the controls as desired (if necessary, read chapter 1.3
“Control elements” once again).
3. Check your settings by making A/B comparisons using each channel’s IN/OUT switch.
3.2.2 Noise reduction during recording
The noise reduction effect may be increased by using the DENOISER not only during playback but also when
recording. For this purpose, insert the unit directly after the master output of the mixer into the recording path
of the master or multitrack machine. Set up the unit as described in the previous section “Noise reduction
during playback”.
In particularly difficult cases, we recommend using the DENOISER both during recording and playback.