Behringer SNR2000 Manuel D’Utilisation

Page de 26
25
DENOISER SNR2000
6. SPECIFICATIONS
System specifications
Bandwidth
5 Hz to 100 kHz, +0/-3 dB
Noise
> 104 dBu, fully off
THD
0.02% typ. @ +4 dBu, 1 kHz, Gain 1
Crosstalk
< -85 dBu
Expander section
Threshold
variable (-40 to +20 dBu)
Release
variable (0.05 to 6 seconds)
Ratio
variable (1:1 to 1:6)
Filter section
Sensitivity
variable (-50 to +10 dBu)
Release
variable (0.06 to 1.2 seconds)
Cut-off
variable (800 Hz to 6 kHz)
Function switches
Channel IN/OUT
Relay controlled hard-bypass
Expander IN/OUT
Activates the expander section
Filter IN/OUT
Activates the filter section
Auto
Activates the automatic filter circuitry
Couple
Link feature for stereo tracking
Indicators
8 LED gain reduction
1/2/4/6/10/15/20/30 dB
8 LED filter bandwidth
1/1.5/2.2/3.3/5/7.5/12/20 kHz
LED indicator for each function switch
Power supply
Mains voltages
USA/Canada
120 V ~, 60 Hz
U.K./Australia
240 V ~, 50 Hz
Europe
230 V ~, 50 Hz
General export model
100 - 120 V ~, 200 - 240 V ~, 50 - 60 Hz
Fuse
100 - 120 V ~: T  320 mA  H
200 - 240 V ~: T  160 mA  H
Power consumption
9 Watts
Mains connection
Standard IEC receptacle
Physical
Dimensions (H x W x D)
1 3/4" (44.5 mm) x 19" (482.6 mm) x 8 1/2" (217 mm)
Net weight
approx. 3 kg
Shipping weight
approx. 4.2 kg
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be
made  from  time  to  time  to  existing  products  without  prior  notice.  Specifications  and  appearance  may  differ  from  those  listed  or
illustrated.