Chapter 5: Configuring the DN965X
DN9650/DN9652 Network Bridge
22
Operator Manual
Updating the unit’s host software
The upgrade procedure involves transferring a number of files individually to the 
DN965X unit.  The files are supplied in a single TAR file.  Before you can begin the 
upgrade these files must be ‘unzipped’ to a location that is easily accessible from your 
computer.
The TAR file will contain all of the files required to update any type of unit, as listed in 
the following table, which also shows the recommended order of upload.  Although this 
order is not critical, it is important that you upload the 9650apps.img file last, as this 
file triggers a reboot of the DN965X unit.
Table 3: TAR files and recommended file upload order
>> To update the host software of the DN965X
Do not switch the unit off during the software update procedure.
1
In the Unit Software section of the configuration window, click Update 
Software.
2
You can locate the file by using the browse facility.  Click Browse and navigate to 
the file you want, then select the file.
Filename
Recommended upload order
DN9650
DN9652
9650_ramdisk.gz
1
1
unmanagedredboot.bin
2
2
vmlinux26.bin 3
3
fpgas/dn9650_asrc.bin
4
4
fpgas/dn9650_bridge.bin
5
N/A
fpgas/dn9652_bridge.bin
N/A
5
9650apps.img
6
6