K
fig 1.4
CINDER
BLOCK
SOLID
CONCRETE
C
Installation to Solid Concrete or Cinder Block
•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING
1
CUT
AW
AY
 VIEW
INCORRECT
CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
K
Drill holes and insert anchors (
K).
Place plate (
AA) over anchors (EE) and secure with screws (DD).
Tighten all fasteners.
  C
K
  J
concrete
surface
•  Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Always attach concrete expansion anchors directly 
to load-bearing concrete.
•  Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable),
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8" (16 mm), custom
fasteners must be supplied by installer.
WARNING
Make sure that wall arm bracket (
C) is level, use it as
a template to mark four mounting holes. Drill four 5/16"
(8 mm) dia. holes to a minimum depth of 2.5" (64 mm).
Insert concrete anchors (
K) in holes flush with wall as
shown (right). Place wall arm bracket over anchors and
secure with #14 x 2.5" screws (
J). Level, then tighten all
fasteners.