Turn off the projector and unplug the AC power cord. Let 
the projector cool for at least 45 minutes.
Loosen the screw and open the lamp cover. Pull out the 
lamp by using the built in handle.
1
3
Replace the lamp with a new one. Make sure that the 
lamp is properly and fully inserted. 
4
Open the filter cover (p.62). 
2
Connect the AC power cord to the projector and turn on 
the projector.
6
Follow these steps to replace the lamp.
Reset the Lamp counter (p.65).
5
Note:
 • Be sure to insert the lamp in the correct direction.
 • Do not reset the Lamp counter when the projection lamp is
not replaced.
Lamp Replacement
For continued safety, replace with a lamp  of the 
same type. Do not drop the lamp or touch the 
glass bulb! The glass can shatter and may cause 
injury.
Allow a projector to cool for at least 45 minutes 
before you open the lamp cover. The inside of the 
projector can become very hot.
CAUTION
CAUTION
When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the 
screen and LAMP REPLACE indicator lights orange. Replace the lamp with a new one promptly. The timing 
when the LAMP REPLACE indicator should light is depending on the lamp mode.
Top Panel
LAMP REPLACE indicator
Lamp replacement icon
Note:
 • The Lamp replacement icon will not appear when
the Display function is set to “Off” (p.52) or during
“Freeze” (p.33)
7
Close the lamp cover and secure the screw. 
Lamp
Handle
Lamp cover
Filter cover
Screw
Maintenance and Care
8
Close the filter cover.