4-14
• Manual 
Adjustment
1
Adjust color slide bars and judge image color by eye or meter. A user-
defined color "adjustment" can be applied.
2
Use this submenu if you do not have specific color coordinates in mind 
and will judge color performance by eye or meter. As for Meter 
Adjustment, each color control actually defines new x/y coordinates for 
that color and changes its hue. The main colors (red part of red, green 
part of green and blue part of blue) adjust the intensity of that color 
component, while the modifying colors (e.g. green part of red and blue 
part of red) modify the x and y value and change the hue of that color. 
At the same time the main colors also are used to control the color of 
the white point.
Hot-Key Settings
Assign a different function to the hot-key on the remote control by highlighting 
the function in the list and pressing ENTER. Choose a function that does not 
already have a dedicated button, and assign the hot-key to that function, 
allowing you to quickly and easily use the chosen function.
Service
• 
Projector Info: Display current projector settings (read-only).
• 
Factory Reset: Restore all settings to their default value. It will not reset 
network but it will reset RS232.
• 
Test Pattern: Choose the desired internal test pattern to display, or select 
OFF to turn off a test pattern.
• 
Phosphor Index: The Phosphor index synchronizes the phosphor wheel 
with the filter wheel and DMD. The index defines the delay between the 
wheel and the DMD. When the Phosphor index is adjusted, it will impact 
the smoothness and contouring of the R/G/B gray level.
• 
Filter Index: The Filter index synchronizes the filter wheel with the phosphor 
wheel and DMD. The index defines the delay between the wheel and the 
DMD. When the filter index is adjusted, it will impact the smoothness of the 
white color space without contouring, similar to the phosphor index 
behavior.
• 
Error log: Show the projector error log for debug.
• 
Mode Adjustment: Fine tune the H and V start position for a signal in the 
EDID timing table and record the values in the system to override the timing 
table. The settings must be "Saved to Record" before exiting the menu, or 
they will be lost. To revert to original timing table settings, each setting must 
be manually cleared. Factory Defaults will not clear these override settings.
• 
Laser Diode Info: Display current laser banks status and temperature 
information.
• 
High ambient temperature warning: Show the warning message the when 
the ambient temperature is over 35°C.