Siemens 7ML19985AB01 Manuel D’Utilisation

Page de 112
RECTANGULAR AREA X VELOCITY,  P3 = 13
‘U’ parameters required *
‘U’ parameters calculated **
U0 = channel width B
 
U1 = area (h)
*obtain from manufacturer’s specifications.
**
calculated by OCM-3. May be viewed by accessing ‘U’ parameter.
Reference
ABSOLUTE CALCULATION,  P4 = 0
¤
 
For flows that can be calculated by the equation:
q = 1/1000 x B x h x V
where :
q = flow rate in l/sec
B = channel width in cm
h = head in cm
V = velocity in cm/sec   
RATIOMETRIC CALCULATION,  P4 = 1
¤
 
For flows that can be calculated by the equation:
q = q
cal
 x A/A
cal
 x v/v
cal
where :
q = flow rate
q
cal
 = flow rate at maximum head
h = head
h
cal
 = maximum head
v = velocity 
v
cal
 = velocity at maximum head
¤
 Refer to Operation \ Flow Calculation.
7ML19985AB01
OCM III
82