Siemens 7ML19985AB01 Manuel D’Utilisation

Page de 112
EGG-SHAPED AREA X VELOCITY,  P3 = 19 
‘U’ parameters listed *
‘U’ parameters calculated **
U0 = top radius 
R
U3 = area (h)
U1 = bottom radius 
r
U2 = axial displacement
d
*
obtain from manufacturer’s specifications.
**
calculated by OCM-3. May be viewed by accessing ‘U’ parameter.
Reference
ABSOLUTE CALCULATION,  P4 = 0
¤
 
For flows that can be calculated by the equation:
q = 1/1000 x A x v
where :
q = flow rate in l/sec
v = flow velocity in cm/sec
RATIOMETRIC CALCULATION,  P4 = 1
¤
 
For flows that can be calculated by the equation:
q = q
cal
 x A/A
cal
 x v/v
cal
where :
q = flow rate
q
cal
 = flow rate at h
cal
A = cross sectional area of flow
A
cal
 = cross sectional area of flow at h
cal
v = flow velocity
¤
 Refer to Operation \ Flow Calculation.
7ML19985AB01
OCM III
94