Lanier FX-061 Fascicule

Page de 2
 
 
Lanier Worldwide, Inc.  
2300 Parklake Dr., N. E. 
Atlanta, GA 30345-2979 
Emergency Telephone:  (800) 526-4371 
 
 
MATERIAL SAFETY DATA SHEET
 
 
Section 1: Chemical Product and Company Information 
 
Identity: 
 
Black Print Cartridge for M3110 / 3120 
 
 
MSDS No. 
 
FX-061 
Product ID: 
491-0273 
 
Issued:  07/13/00 
 
Synonyms  
& Common 
Names: 
 
Uses: 
 
Chemical  
Formula: 
 
 
 
Ink, Ink Cartridge, Print Cartridge 
 
Lanier 3110, 3120, 3750 Fax 
 
 
Liquid  
 
Supersedes: 
Date: 
Prepared by: 
Approved by:  
European Contact: 
12/01/98 
07/13/00 
EH&S Department 770-493-9500 
Larry Choskey, EHS Manager 
Lanier Worldwide , WSM Europe,  
Walter Fricke,  
Im Taubental D-41468 Neuss, Germany 
+49-2131-387-177 
Section 2: Composition / Information on Ingredients 
 
PERCENT 
CAS No. 
EXPOSURE LIMITS 
SOURCE 
Water 
85 - 95 
7732-18-5 
Not listed 
n/a 
Tetraethylene Glycol 
1 - 2 
112-60-7 
Not listed 
n/a 
Glycerol 
3 - 7 
56-81-5 
15mg/ m
(1)
 
10mg/ m
(1) 
OSHA PEL ACGIH TWA 
Black dye 
1 - 3 
Trade secret (2) 
Not listed 
N/a 
Triethanolamine 
.5 - 2  
102-71-6 
5mg/ m
 
n/a 
 
 
 
 
 
(1) Mist only     (2) New Jersey Trade Secret Registration no.:  80100451-5008p 
 
Section 3: Hazards Identification 
HMIS Rating: 
FLAMMA BILITY = 1                                                       HEALTH = 1 
REACTIVITY = 0                                                            SPECIAL = none 
 
Health Hazards 
 
 
Short Term Exposure 
Long Term Exposure 
Inhalation 
 
 
Information on ink constituents indicates short-term 
harmful health effects are not expected from vapor 
generated during intended use at ambient conditions.
 
No adverse chronic effects known from 
vapor generated during intended use at 
ambient conditions.
 
Skin Contact 
Tests o n inks indicate low acute dermal toxicity.  Tests 
indicate inks are not dermal sensitizers.  Inks may be 
slightly irritating to skin.
 
No adverse chronic effects known.
 
Eye Contact 
Tests on inks indicate slight conjuctival irritation.
 
No adverse chronic effects known.
 
Ingestion 
Tests on inks indicate low acute oral toxicity.  May cause 
GI discomfort.
 
No adverse chronic effects known.
 
 
Section 4: First Aid Measures 
 
Inhalation: 
Remove to fresh air if effects occur.   Get medical 
attention if needed.  
 
Eye Contact:
    
In case of contact, immediately flush eyes with 
water for 5 minutes.  Get medical attention if 
needed. 
Skin Contact: 
Wash with soap and water. 
Ingestion:          Dilute stomach contents with several glasses 
of water.  Get medical attention. 
 Section 5: Fire Fighting Measures 
Suitable extinguishing media:  CO
2
, dry chemical, foam or water. 
Extinguishing media which may not be used for safety reasons:  none