3. ON LINE MODE
 
 
EO13-33002 
 
3.5 Automatic Calibration Setting
 
3- 9 
3.5  Automatic Calibration Setting 
Whether to activate the automatic calibration at a power on time or not is selectable in the Automatic 
Calibration Mode.  When the automatic calibration is activated, the printer feeds the media for about 160 
mm each time the power is turned on or the Top Cover is opened, to detect a print start position. 
 
„
    How to Choose an Automatic Calibration Setting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTES: 
1.  When this parameter is set to ON, the printer performs an automatic calibration each time the power is turned 
on or the top cover is closed.   
2.  When this parameter is set to ON, the media length, effective print length, and sensor type specified in the 
command are ignored. 
3.  When “ON REFLECT” is selected, the lowest voltage detected by the black mark sensor is considered as a 
black mark level.    And, the sum of this voltage and the manual threshold voltage will be adopted as a 
threshold.  
4.  When “ON TRANS” is selected, the highest voltage detected by the feed gap sensor is considered as a gap 
level.    After subtracting the manual threshold voltage from this voltage, the result will be adopted as a 
threshold.  
5.  The printer feeds about 160 mm long media to detect a black mark/gap, measure the media pitch, and 
determine the threshold.    When the printer detects more than two black marks/gaps during this media feed, 
the automatic calibration is stopped where 1 mm short of the bottom of a black mark or gap.    If the printer 
cannot detect a black mark/gap under this condition by feeding the media for up to 500.0 mm, the printer will 
stop, resulting in a paper jam. 
[PAUSE] 
<1>RESET 
 
ON LINE 
B-SX8T                Vx.x 
Press and hold the [RESTART]
key for 3 seconds or longer. 
PAUSE                    52 
B-SX8T                Vx.x 
Press the [FEED] or [RESTART] key 
until <6>AUTO CALIB is displayed. 
Press the [PAUSE] key to stop printing. 
 
The number of remaining print count   
NOTE: When the [PAUSE] key is pressed during printing, the number of
remaining print count is displayed. 
<6>AUTO CALIB 
<6>AUTO CALIB 
OFF 
[PAUSE] 
Press the [PAUSE] key to enter the automatic calibration. 
 
Choose an automatic calibration using the [FEED] or [RESTART] key.
• 
OFF: Not 
activated 
• 
ON TRANS.:  Transmissive (Feed gap) sensor is activated. 
• 
ON REFLECT: Reflective (Black mark) sensor is activated.   
<6>AUTO CALIB 
 
[PAUSE] 
[FEED] or [RESTART]