2.1 Self-diagnostic Test
 
2-11 
2.1.4  Self-Diagnostic Test and Result Print Out 
When the Maintenance Counter/Parameter Settings is printed, the message returns to “<1>DIAG. Vx.x”.  
Press the [PAUSE] key twice. 
 
The Self-Diagnostic Test is ready.  Press the [PAUSE] key to start. 
 
 
 
The printer starts a self-diagnosis, and prints out the result.  During printing, the message below appears on 
the display. 
 
 
 
After printing is completed, the display returns to “<1>DIAG. Vx.x”. 
NOTE:  If an error occurs, an error message appears, the printer stops printing.  After clearing the error, press the 
[PAUSE] key to return the display to “<1>DIAG.Vx.x”.  The printer does not restart printing automatically. 
 
• Print Sample 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTES: 1.  Print conditions: Print speed: 4”/sec., Sensor: No sensor, Printing method: 
Thermal transfer/Direct 
thermal
(*1)
, Media length: 87 mm, Issue mode: Batch printing 
 
(*1) Depends on the printing mode setting. 
 
2.  Software version No., Part No. of ROM and checksum vary according to the 
 
 
software version of PROGRAM ROM. 
 
3.  The last two digits of the checksum are usually “00”. 
 
4.  When Kanji ROM is not installed, the checksum becomes “0000”. 
 
5.  The symbol “°” of “°C” may not be printed depending on the type of character code. 
 
PROGRAM B-SX8T 
 
MAIN 
15OCT2005 V1.0A: 1A00 
 
BOOT 
20SEP2005 V1.0:  8500 
FONT AD00 
KANJI GOTHIC 
:9F00 
 MINCHO 
:7400 
EEPROM OK 
SDRAM 16MB 
SENSOR1 00000000, 
00000111 
SENSOR2 [H]23°C 
[A]22°C 
 
[R]4.2V [T]2.5V 
PE LV. 
[R]1.2V  [T]4.3V 
M THRE. 
[R]5.0V  [T]5.0V 
 [RANK]1 
305DPI 
EXP.I/O NG 
EX.232C NG 
SIO NG 
 
NG 
STRIP NG 
RFID 
OK  #00RV972   (EU0) 
(1) 
 
 
(2) 
(3) 
 
(4) 
(5) 
(6) 
(7) 
 
(8) 
(9) 
 
(10) 
(11) 
(12) 
(13) 
(14) 
<1>DIAG.  Vx.x 
AUTO DIAGNOSTIC 
<1>DIAG.  Vx.x 
CHECKING & PRINT