2. SYSTEM MODE
 
 
EO13-33002 
 
2.5 Sensor Adjustment
 
2-59 
 
How to Enter the Sensor Adjustment Mode 
While pressing the [FEED] and [PAUSE] keys at the same time, turn on the printer.  Hold both keys until 
the “<1>DIAG. Vx.x” Message appears. 
 
 
Press the [FEED] key 4 times.  The printer is at the start of the Sensor Adjustment menu. 
 
 
 
 
2.5.1  Thermistor Status Display 
When “<5>SENSOR ADJ.” appears, press the [PAUSE] key to display the following. 
 
 
 
 
 
 
 
 
 
 
 
Press the [PAUSE] key to show a real-time black mark sensor status. 
 
 
2.5.2  Black Mark Sensor Adjustment 
 
 
 
 
 
Follow the procedure below to store a media level voltage of the black mark sensor. 
(1)  Load a tag stock in the printer so that the Black Mark Sensor detects a print area (no black mark). 
(2)  Press and hold the [RESTART] or [FEED] key for more than 3 seconds. 
 
 
 
 
(3)  Remove the tag stock from the printer. 
(4)  Press the [PAUSE] key to show a real-time Feed Gap Sensor status. 
 
 
<1>DIAG.   Vx.x 
<5>SENSOR ADJ. 
<5>SENSOR ADJ. 
[REFLECT] 2.8V* 
When storing a media level voltage is completed, “*” appears. 
<5>SENSOR ADJ. 
[H]20°C  [A]22°C 
Print Head Thermistor Status 
  0 to 86 °C 
Ambient Temperature Thermistor Status 
  0 to 86 °C 
<5>SENSOR ADJ. 
[REFLECT] 3.8V 
Real-time status detected by the Black Mark Sensor 
  0.0V to 5.0V