4. SET UP PROCEDURE 
EO1-13016 
4.1 Requirements for Operation
 
4- 1 
4.  SET UP PROCEDURE 
4.1  Requirements for Operation 
This printer has the following requirements: 
Serial interface Type 
• 
The TOSHIBA TEC POS terminal to be connected must have a serial port. 
• 
To communicate with the TOSHIBA TEC POS terminal, an RS-232C interface cable is required. 
 
RS-232C cable........ 25 pins 
Parallel Interface Type 
• 
The TOSHIBA TEC POS terminal to be connected must have a Centronics parallel port. 
• 
To communicate with the TOSHIBA TEC POS terminal, a Centronics interface cable is required. 
 
Centronics cable ..... 36 pins 
 
Interface Cables 
For the serial interface model, use the CBLST-50-2-QM serial printer cable available from TOSHIBA 
TEC or equivalent.  For the parallel interface model, use the Centronics cable which satisfies the 
following pin configuration and the specification of the connector.  
To prevent the emission and receipt of electrical noise, the interface cable must meet the following 
requirements: 
• 
Fully shielded and fitted with metal or metalized connector housings. 
• 
Kept as short as possible. 
• 
Should not be tightly bundled with the power cord. 
• 
Should not be tied to power line conduits. 
 
RS-232C cable pin configuration 
 
POS terminal side 
Printer side 
 
D-SUB 9-pin female 
D-SUB 25-pin male 
PIN No. 
Signal 
 
PIN No. 
Signal 
Case 
FG 
 
FG 
RXD 
 
TXD 
TXD 
 
RXD 
CTS 
 
RTS 
DTR 
 
DSR 
GND 
 
GND 
DSR 
 
20 
DTR 
 
Centronics cable pin configuration 
 
POS terminal side 
Printer side 
 
D-SUB 25-pin male 
IEEE1284-B receptacle 
PIN No. 
Signal 
 
PIN No. 
Signal 
/STROBE 
 
/STROBE 
2-9 
PD1-8 
 
2-9 
PD1-8 
10 
/ACK 
 
10 
/ACK 
11 
BUSY 
 
11 
BUSY 
12 
PERROR 
 
12 
PERROR 
13 
SELECT 
 
13 
SELECT 
14 
/AUTOFD 
 
14 
/AUTOFD 
16 
/INIT 
 
31 
/INIT 
15 
/FAULT 
 
32 
/FAULT 
17 
/SELECTIN 
 
36 
/SELECTIN 
18-25 
GND 
 
19-30 
GND 
 
 
 
15-18 
N.C. 
 
 
 
33-35 
N.C. 
 
NOTE:  For details of the interface cable, contact your nearest TOSHIBA TEC representative.