Tally Genicom 5040 Manuel D’Utilisation

Page de 142
User guide
Specifications
83
Rated current intake
Operation (maximum):
US: 1.30 A; EU: 0.59 A 
Standby:
US: 0.11 A; EU: 0.072 A
Apparent power 
consumption
Operation (maximum):
US: 89.7 VA; EU: 93.6 VA 
Standby:
US: 88.8 VA; EU: 11.4 VA
True output
Operation (maximum): 
US: 70.0 W; EU: 73.0 W 
Standby
US: 6.9 W; EU: 8.9 W
Noise
Sound output level 
Sound pressure level
L
WAd
: 7.1 dB in operation
L
pAm
: 55 dB in operation
Paper feed
Friction feed
MTBF (Mean Time 
Between Failures)
10,000 power on hours at 25% DC (duty cycle)
Dimensions
Height: 168 mm, Width: 378 mm, Depth: 280 mm
Weight
Standard = 9,10 kg, MSR-H = 9,95 kg
Service life
Print head
Ribbon
300 million dots/pin (normal copy mode) 
10 million characters in ANK DRAFT10 cpi 
Environmental conditions
Operation 
Temperature
Rel. humidity 
Climate
+10° to +35°C
15 to 75%
IEC/EN 60721-3-3, class 3K2
Storage
Temperature
Rel. humidity 
Climate
-5° to +45°C
5 to 95%
IEC/EN 60721-3-1, class 1K3
Transport
Temperature
Rel. humidity 
Climate
-20° to +60°C
5 to 95%
IEC/EN 60721-3-2, class 2K2